RHE 42
Ex c Field Mount
With its advanced digital signal processing capability and in conjunction with our sensors, the RHE 42 can achieve an ultimate mass flow measurement uncertainty of 0.05 %, making it ideal for both filling and bottling or any kind of high accuracy/reliability plant flow or density measurement. Connectivity includes a full suite of communications buses including Foundation Fieldbus and Modbus TCP/IP. The RHE 42 is a well specified transmitter relevant for large scale plant and project opportunities.
- Measures Mass Flow, Volumetric Flow, Density and Temperature
- Outputs 2 x Analog, 2 x Frequency/Pulse, 2 x Digital Status
- Inputs 2 x Digital
- PC USB / RHECom, RS 485 / Modbus RTU, Modbus TCP, Foundation Fieldbus and Profibus PA
- Optional Backlit Color LCD
- Installation in Hazardous Area
- Rheonik Assurance Factor®
General Specifications
Enclosure Material | Powder coated aluminum | |
Enclosure Rating | IP65/Type 4, optional IP66-67/Type 6 | |
Ambient Temperature | -20 to +60°C / -4 to +140°F, optional -40°C to +65°C / -40°F to 149°F Integral version depends upon fluid temperature, refer to next page | |
Dimensions | Enclosure approx. 144 x 108 x 139 mm / 5.67 x 4.25 x 5.47 in Weight approx. 2.3 kg / 5.1 lbs | |
User Interface and Configuration | Local Display Version High contrast backlit LCD color display and 3 x through-glass operator buttons. Configure locally or with RHECom software Reduced display visibility below -10°C / 14°F | Blind Transmitter Version No local controls. Configure through RHECom software package |
Connection to Sensor | Integral/Compact to sensor or remote mount with 3m/10m cable | |
Cable Entries | 2 x ½” NPT for power and I/O | |
Computer Connection | Via Modbus RTU to PC | |
Totalizers | 6 x resettable forward, reverse and net totalizers for mass and volume 2 x non-resettable totalizers for mass and volume | |
Analog Outputs | Up to 2 x 4-20mA outputs, active or passive. Intrinsically safe versions available | |
Pulse/Freq/Status Outputs | Up to 2 configurable pulse/frequency/status outputs (IEC60946). Max. 10kHz. Intrinsically safe versions available (open collector) | |
Digital Inputs | Up to 2 configurable control inputs (IEC60946). Intrinsically safe versions available | |
Digital Data Communications | HART, Modbus RTU, Ethernet (Modbus TCP/IPv4), Foundation Fieldbus H1 (FISCO), Profibus PA | |
Power Supply | 12-24 VDC +/- 10%, 2W typical, 4W maximum | |
Hazardous Area Approvals | ATEX/IECEx and cCSAus |