RHM 06

FLOW SENSOR

The RHM 06 is a low risk, low maintenance solution for critical flow applications everywhere. High pressure and temperature options comined with a selection of wetted material make the RHM 06 a true fit and forget device.

  • Range: 0.1 kg/min up to 36 kg/min
  • Pressure: up to 1662 bar (24105 psi)
  • Temperature: -196°C (-321°F) up to +350°C (662°F)
  • Accuracy: 0.1 % of rate
  • Materials: SS 316L / SS 316Ti, Super Duplex – 1.4410, Alloy C22 – 2.4602, Tantalum – UNS R05200
  • Process Connection: ½" up to 1"
CONFIGURE
CATEGORY Small Size Sensors, H2 Filling Station, Chemical Injection, Fuel Consumption, Refrigerant Filling, Oil Measurement, Painting/Coating Lines, Plastics Production

Performance Data

Performance Data

Flow Measurement Uncertainty
Standard: 0.20 % of rate
Enhanced: 0.15 % of rate
Premium: 0.10 % of rate
Ultimate: 0.05 % of rate – requires RHE 40 Series transmitter
Low Flow Calibration: 0.10 % of rate – requires RHE 40 Series transmitter
Customized Calibration: Consult factory

Low flow calibration focuses on the range from ½ × Qₙₒₘ downwards to lower flow rates than on other calibrations. Often used for low pressure gas or very viscous liquids. Customized calibration uses specific calibration points according to customer requirements.

Flow Measurement Repeatability
Standard Sensors: ±0.1 % of rate
Premium Sensors: ±0.05 % of rate

Temperature Measurement
Better than ±1 °C

Density Calibration (Liquid)
Standard: ±0.001 kg/l uncertainty
Premium: ±0.0005 kg/l uncertainty – requires High Accuracy or Focused Calibration Option

Reference conditions: 18–24 °C Water @ 1–3 bar

Measurement Tube Pressure Ratings
Measurement Tube Pressure Ratings

The maximum pressure (pₘₐₓ) of a sensor is determined by its lowest rated part: the measurement tube (see table below), the connection block (see datasheet) or the process connection (see corresponding standards or manufacturer information).

If applicable, the material of a connection block is always SS 316L. For sensors in sealless versions, the material of the process connection is usually the same as the material of the measurement tubes. In special cases, the material may differ.

 

50 °C
122 °F

120 °C
248 °F

210 °C
410 °F

350 °C
662 °F

SS 316L (standard)
Low Pressure

213 bar
3089 psi

189 bar
2741 psi

160 bar
2321 psi

136 bar
1972 psi

Alloy C22

300 bar
4351 psi

267 bar
3872 psi

227 bar
3292 psi

189 bar
2741 psi

SS 316L (standard)
High Pressure

580 bar
8412 psi

516 bar
7484 psi

435 bar
6309 psi

370 bar
5366 psi

Super Duplex *
Low Pressure

580 bar
8412 psi

516 bar
7484 psi

435 bar
6309 psi

 

Super Duplex *
Medium Pressure

910 bar
13198 psi

847 bar
12285 psi

760 bar
11023 psi

 

Super Duplex *
High Pressure

1234 bar
17898 psi

1149 bar
16665 psi

1030 bar
14939 psi

 

Super Duplex *
Very High Pressure

1722 bar
24975 psi

1603 bar
23249 psi

1438 bar
20856 psi

 

Tantalum

118 bar
1711 psi

91 bar
1320 psi

74 bar
1073 psi

 

* Minimum operating temperature for Super Duplex stainless steel is -40 °C. Maximum pressure may be lower depending on the design type.

Uncertainties and flow measurement turn-down
Uncertainties and flow measurement turn-down

The turn down capability from Qₙₒₘ of the flow sensor is driven mainly by its zero point stability. At the very low end of the measuring range the uncertainty (u) is dominated by zero point stability.

• Zero point stability of a standard sensor with general accuracy calibration: 0.00086 kg/min (0.0019 lbs/min).
• Zero point stability of a premium sensor with high accuracy or focused calibration: 0.00058 kg/min (0.00128 lbs/min).
• uncertainty = calibration uncertainty, if: flow ≥ (zero point stability / (base uncertainty/100))
• uncertainty = (zero point stability/Q)*100, if: flow < (zero point stability / (base uncertainty/100))

Uncertainties from environmental and process conditions
Uncertainties from environmental and process conditions

If sensors are not zeroed at operating conditions, minor additional uncertainties can arise from elevated temperatures and pressures:

• ±0.001074% of maximum flow per °C
• ±0.000857% of maximum flow per bar

Process temperature effect on density:
• Additional uncertainty of ±0.000064 g/cm³ per °C difference from calibration temperature with standard density calibration.
• Additional uncertainty of ±0.000054 g/cm³ per °C difference from calibration temperature with enhanced density calibration.
• This effect can be mitigated by a simple field density adjustment at operating conditions.

Process pressure effect on mass flow:
• The effect of pressure on flow measurement is 0.0001% of rate per bar. Compensation is possible by pressure sensor input (analog input or digital write) or manual value entry into the transmitter.

Process pressure effect on density:
• The effect of pressure on density measurement is 0.00007 g/cm³ per bar. Compensation is possible by pressure sensor input (analog input or digital write) or manual value entry into the transmitter.

Applying Premium calibration to higher pressure, special materials and/or non-standard temperature models may show higher zero uncertainties (up to 3 times higher than standard sensor).

Couldn’t find what you were looking for?

Contact us with your specification for assessment and availability of other sensor configurations.

Other wetted materials may be possible for chemical compatibility, lower pressure drop, abrasion allowance or other application specific requirements. Rheonik can provide nearly any material for the wetted parts.