RHM 15
FLOW SENSOR
The RHM 15 is an all-purpose meter suitable for liquid processing plants. A wide application flow range capability allows for commonality of installation across numerous lines – a real benefit to owners and operators.
- Range: 0.5 kg/min up to 240 kg/min
- Pressure: up to 1282 bar (18593 psi)
- Temperature: -196°C (-321°F) up to +350°C (662°F)
- Accuracy: 0.1 % of rate
- Materials: SS 316L / SS 316Ti, Alloy C22 – 2.4602, Super Duplex – 1.4410, Tantalum – UNS R05200
- Process Connection: ¾" up to 2 ½"
General Specifications
Nominal Flow (Qₙₒₘ)* | 180 kg/min (396.8 lb/min) |
Maximum Flow (Qₘₐₓ)* | 240 kg/min (529.1 lb/min) |
Typical Minimum Flow (Qₘᵢₙ)* | 0.5 kg/min (1.1 lb/min) |
Operating Temperature | Fluid temperature range options cover from -50 °C (-58 °F) to +210 °C (+410°F). |
Ambient Temperature | Standard -50 °C (-58 °F) to +80 °C (+180 °F). |
Pressure Ratings | Up to 400 bar (5801 psi) – depending on the material |
Electrical Connection Sensor | M20 x 1.5 standard cable entry |
Sensor Enclosure Materials | SS 304 (standard), SS 316L (optional) |
Enclosure Type | IECEX tested protection class IP66 (IP66 is mostly equivalent to NEMA 4X) |
Wetted Materials | Flow tubes SS 316Ti, Alloy C22, Super Duplex, Tantalum (see datasheet) |
Process Connections | Nearly any – the Rheonik AnyPipeFit Commitment covers a wide range of process connection types and sizes. Consult factory for types/sizes not listed (see datasheet). |
Pressure Rating Compliance | Pressure Equipment Directive (PED). Others (e.g. CRN) on request. |
Certifications and Approvals | ATEX / IECEx Approvals Zone 0, 1, 2 (see datasheet) |
Testing and Inspection | All sensors are hydro tested, calibrated and supplied with a traceable calibration certificate. Customized calibration and testing services are available |
Project Documentation and QA, Services | Rheonik offers a full set of services for large and complex engineering projects. Typical services offered are, but not limited to: |
Options | Customization services for machine integration available upon request. |
* At Qₙₒₘ pressure drop across a parallel tube sensor will be approximately 1.4 bar (20.3 psi) for H₂O. Sensors can be operated at higher flow rates up to Qₘₐₓ but pressure drop will be higher. Typical Minimum Flow Qₘᵢₙ is the recommended lowest flow rate for an accurate measurement. Sensors will measure flow rates lower than Qₘᵢₙ but uncertainty will increase beyond 1% of rate. The flow rate specifications above relate to standard pressure, parallel tube, connection block sensor versions. Models with higher pressure ratings have increased wall thickness and will have higher pressure drops.